Garbage Chutes

Intake Door

Garbage Chutes

Material of Construction

  • 1
    Stainless steel S.S. 430/S.S. 304
  • 2
    G.I. – Galvanized Iron
  • 3
    M.S. OR CRC
    The thickness of chutes is 1mm /1.2mm /1.6mm per diameter.
Garbage Chutes

Venting

Garbage Chutes

Discharge

1
Simple Discharge Hopper

When a door is not required, We provide a conical hopper to avoid spoiling garbage, and it is directly connected collection trolley.

2
Segregation “Y” hopper
  • It is specially designed for the separation of wet and dry garbage.
  • A mechanically operated rotating flap is provided to divert dry garbage.
  • The electrical control panel operates this System.
3
Fire door Sliding-type

The standard sliding discharge door is mounted on a bearing in a sloping position and held open with a 79-degree U.L. approved fusible link. In the point of fire in the garbage room, the fusible link melts, and the door shuts the mouth of the chute, restricting heat transfer. Mainly used in Garbage Chutes. Control panel.

4
Top hinger type
  • Top hinge type discharge door is held horizontally against gravity by 79 C. fusible link in case of fire, fusible link melts, and fire door closes the upward path of chute restricting heat transfer mainly used in Linen chutes.
 
Garbage Chutes

Chute Cleaning

For cleaning chute, we provide TWO Options

1
Normal Cleaning

This Cleaning has been done by normal water coming from the overhead water tank, and it is operated and controlled by an electrically operated valve. This valve is fitted at the top of the chute and outlet of the water tank. This System operated on manual mode as well as automatic mode, also.

2

Disinfecting and Sanitizing Unit

This Cleaning has been done with normal water with disinfectants, and it is added in line by a Motorized pump. This System is operated and controlled by an electrical control panel. This Unit is installed at roof level. This System operated on manual mode as well as automatic mode also.

General Requirements for Chute Installation at site

Required Minimum Duct Size for Installation

CHUTE DIAMETRE DUCT SIZE / SLAB OPENING
450mm 600mm * 600mm
600mm 750mm * 750mm
750mm 900mm * 900mm

Material of Construction

Garbage Room Sizes Required

TYPE OF CHUTE SIZE OF GARBAGE ROOM  
L W H
STANDARD CHUTE 1500mm 1500mm 2500mm
SEGREGATION CHUTE 2100mm 1500mm 2500mm

Segregation System

As per Municipal norms, segregation of “DRY”(Recycling)& “WET”(Biodegradable) garbage is required and shall be collected in separate collection Bins. We Provide to Segregate and collection of garbage by using one chute. It is fully automatic and one user at a time.